תאי בדיקה בהלם טרמי למערכות  אלקטרוניות, בתעשיות השונות.



 



 
Application
It is necessary test equipment for the aerospace, automotive, home appliances, research and other fields, used for examination and identification of parameters, performance and the use of adaptive of electrical, electronics, automotive electronics, materials and other products, after making high and low temperature impact test. Applied to schools, factories, military, research, and other organizations.
Specs & Technical Parameters UQ3TS-100 UQ3TS-210 UQ3TS -300 UQ3TS -500
Preheat room Upper limit preheat temperature 200 deg c
Heating time R.T.¡«£«200¡ז, about 40min (unload)
Precool room Lower limit precool temperature -75 deg c
Cooling time R.T.¡«-70¡ז, about 90min£¨unload£©
Workroom Temperature shock range -20¡ז¡¢-40¡ז¡¢-55¡ז¡«£«150¡ז
Temperature fluctuation 0.5 deg c
Temperature deviation ¡¡ְ3¡ז
Transform time 15S
Temperature revert time 5min
Temperature revert conditions 3CJ-100S sample load: 10kg Sample exposed
30min in 150¡ז,
5min in ambient temp.
30min in -55¡ז,
3CJ-210S sample load: 15kg
3CJ-300S sample load: 25kg
3CJ-500S sample load: 35kg
Capacity 100 L 210 L 300 L 500 L
Workroom dimensions (cm) D 50 70 70 90
W 50 60 78 80
H 40 50 55 70
Exterior dimensions (cm) D 115 135 135 250
W 195 210 225 225
H 210 220 230 215
Built-in 2 layers stainless steel plate, independent over-temperature protection, accumulated calculagraph, halogen lights, four trundle, 4 standing legs can go up or down, one down-lead hole(on left)








 

 
Application
This product is applicable for the safe performance test of electronic components and parts and provides the reliable test and product selection test, etc; Through the chamber test, the product reliability can be improved and the quality control can be conducted.
Chamber Structure
All functions adopt the computer control with good operation interface so as to ensure the user¡¯s operation and monitoring is more simple and straightforward.
The cold chamber and hot chamber are controlled independently and the chamber doors are independent of each other so as to enlarge the use range of the test chamber (1 chamber for 3 purposes).
A standard lead hole pipe is installed on the top of the chamber in order to facilitate users to lead sensor cable, inspection cable etc into the chamber.
Control System
The switching time between low temperature zone and high temperature zone is not more than 15 sec.
The temperature recovery time is not more than 5 min.
Specs & Technical Parameters
Model UQTS-162 UQTS-340 UQTS-500 UQTS-1000
Workroom dimensions (cm) 45*45*45 60*60*60 80*80*80 100*100*100
Exterior dimensions (cm) 156*87*154.5 171*102*184.5 191*122*226.5 211*142*266.5
Sample zone dimensions 30*30*25 45*45*36 65*65*50 85*85*70
Temperature range A:-20¡ז~200¡ז  B:-40¡ז~200¡ז  C:-60¡ז~200¡ז
Temperature fluctuation ¡¡ְ2¡ז for high temperature and low temperature
Temperature fluctuation ¡¡ְ0.5¡ז (under constant temperature)
Sample zone load 20kg 30kg 50kg 60kg

 

 